Faults, Faults And Remedy - Viega 8350.32 Instructions For Use Manual

Wc flush actuation
Table of Contents

Advertisement

3.4

Faults, faults and remedy

Error
WC does not flush
WC flush runs through
manual actuation is not working
WC flush actuation
Remove the cable of the programming contact.
Place a protective cap onto the contact.
Cause
Power supply failure
Cistern is not yet completely full
No water in cistern, corner valve is
closed
Control defect
Plug connection power pack /
control not made
Plug connection drive unit / control
not made
Dirty seal in filling valve
Dirty seal in drain valve
Plug sequence drive unit / control
incorrect
The mechanism is not connected
to the bow
Remedy
actuate manual flush
Wait until the cistern is sufficiently
full
Open corner valve
Replace control
Create plug connection
Ä „Con‐
necting the control" on page 26
Create plug connection
Ä „Con‐
necting the control" on page 26
Check seal, replace if necessary
Check seal, replace if necessary
Check plug connection, observe
coloured marking
Ä „Connecting
the control" on page 26
Hang the mechanism in the bow
Handling