Faults, Faults And Remedy; Care And Maintenance; Maintenance Tips; Cleaning Cartridge Valve - Viega Visign Instructions For Use Manual

For more 104 equipment set
Table of Contents

Advertisement

3.3

Faults, faults and remedy

Error
Urinal does not flush
Flush is too weak
Urinal flush runs through
3.4

Care and maintenance

3.4.1

Maintenance tips

3.4.2

Cleaning cartridge valve

Visign for More 104 equipment set
Cause
Shut-off valve closed
Cartridge valve dirty or damaged
Shut-off valve is not open far
enough
Cartridge valve dirty or damaged
Cartridge valve dirty or damaged
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the flush plate. Under no circumstances
should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse
the detergent thoroughly with clear water after the prescribed exposure
time. There should be no residue on the components.
The cartridge valve may be cleaned, if necessary. Proceed as follows:
Remove the flush plate from the basic panel.
INFO! Figure shows model 8351.2 as an example.
Remedy
Open shut-off valve
Clean cartridge valve, if necessary,
Ä Chapter 3.4.2 „Cleaning
replace
cartridge valve" on page 11
Open shut-off valve
Clean cartridge valve, if necessary,
Ä Chapter 3.4.2 „Cleaning
replace
cartridge valve" on page 11
Clean cartridge valve, if necessary,
Ä Chapter 3.4.2 „Cleaning
replace
cartridge valve" on page 11