JUKI AB-1351 Instruction Manual page 89

Hide thumbs Also See for AB-1351:
Table of Contents

Advertisement

no.
Zigzag bartacking belt loop length E for sewing
shape no. 7
*
linear bartacking belt loop length F for sewing
shape no. 7
*
Zigzag bartacking belt loop length F for sewing
shape no. 7
*
Belt loop loosening amount for sewing shape no. 7
*
Belt loop width
When the belt loop wdth s changed, the bartackng
*
wdth s automatcally changed accordng to the new
belt loop wdth. At ths tme, the bartackng wdth out-of-
range error (E435) can take place for some set values
of the belt loop wdth.
Belt loop length
*
clamp position correction in lateral direction
Ths swtch s used to correct the lateral poston of the
belt loop clamp when sewng belt loops.
Belt loop clamp longitudinal supply position
correction
Ths swtch s used to correct the longtudnal poston of
the belt loop clamp when feedng belt loops.
Belt loop tension
Ths swtch s used to adjust the belt loop tenson that s
appled by the belt loop drawng devce when the devce
places the belt loop n sewng poston.
+ : Increases the belt loop tenson
- : Decreases the belt loop tenson
→ Refer to
p.24
for detals.
Enable/disable of detection of belt loop drawing device failure
In the case of a lght-weght materal, dsable ths functon settng.
Belt loop cutter section draw-out correction
Ths functon reduces the belt loop draw-out amount to
be grasped by the belt loop drawng devce mmedately
after cuttng of the belt loop whch s not grasped by the
drawng devce.
Enable/disable of the clamp lower position sensor
when sewing the last belt loop
The clamp runs on the garment-body presser when
sewng the last part of the belt loop accordng to the
sewng sze. In ths case, set ths tem to dsable.
* : Data marked with an asterisk (*) are not displayed on the sewing data list screen. they are displayed,
however, from the data entry screen.
: Data in a gray box are not displayed in the standard state. to display them, refer to the Engineer's Manual.
Item
"!-5-5. Adjusting the belt loop tension",
: Enable
: Dsable
: Enable
: Dsable
– 84 –
Input range/
Initial
selection range
value
0 to 10.0
3.0
(mm)
(mm)
0 to 20.0
10.0
(mm)
(mm)
0 to 20.0
10.0
(mm)
(mm)
-2.0 to 40.0
0
(mm)
(mm)
8.0 to 20.0
10.0
(mm)
(mm)
58.0 to 130.0
100.0
(mm)
(mm)
-3.0 to 3.0
0
(mm)
(mm)
-5.0 to 5.0
0
(mm)
(mm)
-100 to 100
-5
Enable
-3.0 to 0
0
(mm)
(mm)
Enable