T-Slot Transducer Holder Removal And Installation - Emerson Daniel 3410 Series Instructions For Use, Maintenance And Installation Manual

Gas ultrasonic flow meters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

Maintenance and Troubleshooting manual
P/N 3-9000-769
Chord "L" Dimension Calculation
The chord "L" dimension is calculated from the meter housing length as well as the
transducer pair lengths, mount lengths, holder lengths, and stalk lengths as shown in
Equation
of the mounts, stalk assemblies, and transducer holders are also etched on the individual
components. The length of the meter body is found on the original calibration sheet
supplied with the meter.
Equation 3-1: Chord "L" Dimension
where
L
chord
L
MeterHousing
L
Mount1
L
Mount2
L
Xdcr1
L
Xdcr2
L
Stalk1
L
Stalk2
L
Hldr1
L
Hldr2
Tip
The transducer "L" dimension is re-calculated when you run the Transducer Swap-out
utility.
3.4
T-Slot transducer holder removal and
installation
WARNING
CONTENTS MAY BE UNDER PRESSURE
When the meter is under pressure, DO NOT attempt to remove or adjust the transducer
holder.
Attempting to do so may release pressurized gases, resulting in serious injury or
equipment damage.
Maintenance and Troubleshooting manual
3-1. The transducer lengths are etched on the transducers. Likewise, the lengths
L
= L
cℎord
−L
−L
= chord "L" dimension (in) (LA ... LD)
= meter housing length (in)
= transducer 1 mount length (in)
= transducer 2 mount length (in)
= transducer 1 length (in)
= transducer 2 length (in)
= transducer 1 stalk length (in)
= transducer 2 stalk length (in)
= transducer 1 holder length (in)
= transducer 2 holder length (in)
+ L
+ L
MeterHousing
Mount1
− L
− L
Xdrc1
Stalk1
Hldr1
− L
− L
Xdrc2
Stalk2
Hldr2
Meter repairs
June 2019
Mount2
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

341434123411Daniel 3414Daniel 3412Daniel 3411

Table of Contents