3.6.1
T-200 transducer capsule assembly removal
This procedure is for removing a transducer capsule assembly from a T-200 transducer
assembly installed in a meter body. The line can be pressurized or at atmospheric pressure.
Procedure
1. Disconnect transducer cabling and chordset from the T-200 transducer assembly by
2. Disconnect the transducer cable nut. Pull the chordset from the transducer
3. Remove the transducer retainer from the transducer stalk by turning the retainer
4. Hold the transducer capsule assembly and carefully pull it out of the transducer
5. Use non-fiber paper to remove any residue of acoustic coupling fluid on the surface
6. Record the serial number of the removed transducer capsule assembly and put it in
7. Repeat Step 1 - Step 6 if more transducer capsule assemblies are to be removed.
3.6.2
T-200 transducer capsule assembly installation
This procedure is for installing a transducer capsule assembly into a transducer assembly
while it is installed in a meter body.
Procedure
1. Ensure that the transducer stalk, retainer and capsule assembly are clean and free of
2. Record the serial number of the transducer capsule assembly to be installed and
Maintenance and Troubleshooting manual
turning the cable nut counter-clock wise.
assembly.
Note
Do not twist the chordset as you disconnect it from the transducer assembly.
counter-clock wise with a 1 1/8" wrench.
stalk.
Note
Do not remove the Kapton tape on the top of the transducer capsule assembly.
of Kapton tape.
a safe place.
debris.
make sure it is correct for the intended transducer assembly.
Table 3-3: T-200 transducer stalk assembly configuration and capsule setting
Stalk assembly configuration
-01
-02
-03
-04
-05
Meter repairs
June 2019
Smart capsule setting
1
2
3
4
5
75