Ao (Api Options); Ap (Api Enable); Bd (Baud Rate) - Digi XTend vB DigiMesh User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

AT commands

AO (API Options)

The API data frame output format for RF packets received. This parameter applies to both the
UART and SPI interfaces.
Use AO to enable different API output frames.
Parameter range
0 - 2
Parameter
Description
0
API Rx Indicator - 0x90, this is for standard data frames.
1
API Explicit Rx Indicator - 0x91, this is for Explicit Addressing data frames.
2
XTend DigiMesh API Rx Indicator - 0x80
Default
2

AP (API Enable)

Set or read the API mode setting. The device can format the RF packets it receives into API frames
and send them out the serial port.
When you enable API, you must format the serial data as API frames because Transparent operating
mode is disabled.
Enables API Mode. The device ignores this command when using SPI. API mode 1 is always used.
Parameter range
0 - 2
Parameter Description
Transparent mode, API mode is off. All UART input and output is raw data and the
0
device uses the RO and RB parameters to delineate packets.
1
API Mode Without Escapes. The device packetizes all UART input and output data in API
format, without escape sequences.
2
API Mode With Escapes. The device is in API mode and inserts escaped sequences to
allow for control characters. The device passes XON (0x11), XOFF (0x13), Escape
(0x7D), and start delimiter 0x7E as data.
Default
0

BD (Baud Rate)

To request non-standard baud rates with values above 0x80, you can use the Serial Console toolbar in
XCTU to configure the serial connection (if the console is connected), or click the Connect button (if
the console is not yet connected).