Page A Mobile Station With Authentication; Originate A Call With Authentication - HP 8924C Application Manual

Cdma mobile station test set
Hide thumbs Also See for 8924C:
Table of Contents

Advertisement

Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication

Page a Mobile Station with Authentication

Paging A Mobile
Station That Has
Registered With The
Test Set

Originate a Call with Authentication

296
13. Select SSD Upd from the CC Order field. The Access annunciator light will light
while the SSD Update order is in progress. If the mobile station responds properly on
the reverse control-channel, "SSD Update Order Successful" will be dis-
played in the upper right-hand portion of the CALL CONTROL screen. The test set and
the mobile station now share common secret data and further call processing functions
with authentication can be tested. If the order failed, then "SSD Update Order
Failed" will appear on the upper right-hand portion of the CALL CONTROL screen.
1. Ensure that the Test Set is in the active state.
Channel" on page 287
2. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
Screen menu. The CALL CONTROL screen will be displayed.
5. Position the cursor on the Display field and select Data.
6. Ensure that the mobile station has registered with the Test Set.
Processing with
Authentication".
7. for information on how to register the mobile station.
8. Select the Page field. The Page annunciator will light while the Test Set pages the
mobile on the forward control channel. If the mobile station responds properly on the
reverse control-channel the message RECC Return will flash momentarily in the up-
per right-hand corner of the CALL CONTROL screen. The Access annunciator will
then light while the Test Set sends the mobile station an alert order on the assigned
voice channel. The mobile station should ring.
9. Press the SEND key on the mobile station. The Connect annunciator will light if the
mobile station properly signals the Test Set. The mobile station is now connected to the
Test Set on the assigned voice channel. The Voice Channel Assignment fields
will be updated, that is, any "-" in the left-hand fields will be replaced with appropriate
information. If page with authentication was successful, "Page w/Auth success-
ful" will be displayed in the upper right-hand portion of the CALL CONTROL
screen. If page with authentication failed, then "Page w/Auth failed" will be dis-
played in the upper right-hand portion of the CAll CONTROL Screen.
1. Ensure that the Test Set is in the active state.
Channel".
2. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select CALL CNTL under the To
Screen menu. The CALL CONTROL screen will be displayed.
See "Turn On The Test Set's Control
for information on how to activate the Test Set.
269.
See "Turn on the Test Set's Control
269.
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Figure 2, "Connecting a Mo-
See "Initialize Call
Figure 2, "Connecting a Mo-

Advertisement

Table of Contents
loading

Table of Contents