Chapter 3, CDMA Receiver Tests
Measuring Receiver Sensitivity and Dynamic Range
7. Arm a single measurement.
Manual Operation:
1. Position the cursor at the Arm field.
2. Press the knob to arm a measurement.
When a measurement is running, the Testing annunciator will be lit.
HP-IB Syntax
"TRIG:MODE:RETR SING" !selects Single measurement mode.
"TRIG:AST 'ARM'" !starts the FER measurement.
"TRIG" !starts the FER measurement and other "active" measurements.
94
CDMA CELLULAR MOBILE RECEIVER TEST
Test Status
FER
Connected
Svc Opt 2
Testing
Errors Counted
Passed
Failed
Frames Counted
Max Frames
Meas Cntl
Max Frames
Traffic
On/Off
Single/Cont
Data Mode
Arm
Confidence
Svc Opt 2
Disarm
95.00
%
FER Spec
Data Rate
0.50
Full
%
Display
Eb/Nt
Interim
----
Results
Yes/No
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amrcvrt.fb
%
Sector A
To Screen
Power
CDMA
-105.0
CALL CNTL
dBm/BW
Traffic
Analog
-15.6
RX TEST
dB
Cnfig
PRNT CNFG
AWGN
Off