Turn On The Test Set's Control Channel; Register A Mobile Station - HP 8924C Application Manual

Cdma mobile station test set
Hide thumbs Also See for 8924C:
Table of Contents

Advertisement

3. Select CALL CNFG from the To Screen menu. The CALL CONFIGURATION
4. Verify that the Test Set's configuration information is appropriate for the mobile station

Turn On The Test Set's Control Channel

1. If not already done, condition the Test Set.
2. If not already done, configure the Test Set.
3. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
4. Select the Active field. The Active annunciator will light when the control channel

Register a Mobile Station

1. Ensure that the Test Set is in the active state.
2. Connect the mobile station to the Test Set as shown in
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
5. Position the cursor on the Display field and select Data.
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the CALL CONTROL Screen to Test Call Processing Functions
g Ch Loc: (right-hand field, NAMPS system type only) - Select the narrow analog
channel location which will be assigned to the mobile station by the Test Set as
either an initial channel location assignment or as a handoff channel location
assignment. The choices are Lower (10 kHz below standard wide analog channels),
Middle (centered at the wide analog channel), Upper (10 kHz above the standard
analog channel) or Wide Chan.
(right-hand field) -
h Pwr Lvl:
(VMAC). The VMAC determines the mobile station power level to be used
on the voice channel.
i
DSAT: (right-hand field, NAMPS system type only) - Select the DSAT Color Code
(DSCC) to be used on the voice channel
(right-hand field) - Enter
SAT:
voice channel.
screen will be displayed.
to be tested. Check the following fields:
- Set the number of access channels in the system. This will
a CMAX
determine how many channels must be scanned by the mobile station
when trying to access the Test Set. The value of this field will affect
the time required for the mobile station to connect with the Test Set.
Processing" on page 279
for further information.
for further information.
Screen menu. The CALL CONTROL screen will be displayed.
is turned on.
Channel" on page 287
for information on how to activate the Test Set.
bile Station to the Test Set," on page
Screen menu. The CALL CONTROL screen will be displayed.
Enter the Voice Mobile Attenuation Code
the SAT frequency to be used on the
See "Conditioning the Test Set for Call
See "Configure the Test Set" on page 286
See "Turn On The Test Set's Control
Figure 2, "Connecting a Mo-
269.
287

Advertisement

Table of Contents
loading