HP 8924C Application Manual page 215

Cdma mobile station test set
Hide thumbs Also See for 8924C:
Table of Contents

Advertisement

2. Initialize the Test Set's SSD to zero.
Manual Operation:
1. Select Authen in the To Screen, CDMA list.
If the SSD_A=0 annunciator is lit, performing the
rest of this step is not necessary.
2. Position the cursor in front of the A-Key field.
3. Enter any number within the allowable range of
A-Key values, using the DATA keys. Press the
ENTER key when the number has been
entered.
The SSD_A=0 annunciator should be lit.
The Check Digits field should display a six-digit
1
number.
Entering an A-Key initializes SSD to zero.
The range of values allowed in the A-Key field is 0 to 18446744073709551615.
The number you entered in the A-Key field, along with the MSUT's ESN acquired during registration, are
used by the Test Set to generate the six digits displayed in the Check Digits field. If no Check Digits appear,
make sure an ESN value is displayed in the MS Database field.
The Check Digits are part of the A-Key, and provide a method for checking A-Key validity.
If the ESN changes (for instance when another MSUT is connected to the Test Set and registers) or is cleared,
the Check Digits field will be cleared.
1.
If Kor PCS is selected in the Protocol field, the Check Digits field should be blank.
HP-IB Syntax
"CDMA:AUTH:AKEY '0'" enters all zeroes in the A-Key field.
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\CHAPTERS\amauth.fb
Chapter 6, Authentication Tests
Initializing SSD to Zero
1
215

Advertisement