Chapter 4, CDMA Transmitter Tests
Measuring Access Probe Output Power
Measuring Access Probe Output Power
NOTE:
Test Prerequisites
Recommended Equipment
186
The Test Set can measure access probe power without the need for following this
procedure if the firmware revision is A.06.00 or above. Refer to the HP 8924C Reference
Guide, Fields chapter, Acc Prb Pwr field description.
The Test Set provides call setup for this test, while the HP 859XE displays the
access probes transmitted by the mobile-station-under-test (MSUT) and measures
RF Power. The Test Set is put in a mode that limits the progression of call
processing states, allowing the MSUT to transmit the maximum number of access
probe sequences.
Determine Cable Path Loss
When using cables to connect the equipment, the path loss for the cable(s) should
be determined. The Test Set can be used as a source to measure path loss.
Refer to
"Correcting for RF Path Loss" on page 41
this procedure.
Spectrum Analyzer
HP 895XE
Combiner
if necessary, and then return to
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb