Fault messages & troubleshooting
Continued from previous page
Does the fault appear only sporadically?
Yes
Update software to version 1.69 or higher.
No
Check thermal switch B0 and cooling fan for proper operation. Make sure that the air intake area is
not dirty. Error eliminated?
No
Replace communication cable between motor control and motor for test purposes and perform test
run. Switch unit on "I." Error eliminated?
No
Check the output voltage at connector X2 between terminals 1 and 2. Is approx. 320 V DC
present?
No
Yes
No voltage present. Check voltage supply at
Voltage present. Replace fan motor.
connector X1 on power board. Is it approx.
208 V AC?
No
Check fuses F1 and F1.1. Is one defective?
Yes
Yes
No
Power board defective. Replace component.
Check main contactor Q1 and control board A1.
Service instructions
99