Henny Penny FlexFusion FPE-615 Service Instructions Manual page 73

Electric & gas platinum combi
Hide thumbs Also See for FlexFusion FPE-615:
Table of Contents

Advertisement

DANGER
INFORMATION
Prerequisite Gas connection line connected
Setting without a gas orifice
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
The offset pressure can be measured as an adjustment aid at minimum capac-
ity. This is not a substitute for making the basic gas setting.
Checked for leak tightness outside the unit
Connection pressure checked
Checked for leak tightness inside the unit
Basic gas setting checked
Left side wall removed
1. Remove the gas orifice (see "Converting the gas type").
2. Screw in the adjusting screw for maximum output 10 mm (basic
setting).
3. Manually adjust the rated heat input for minimum power.
4. Manually adjust the rated heat input for maximum power.
a
b
Image: Adjusting screws on the burner
a Adjusting screw for minimum
output (TX40)
Manually adjusting the rated heat input for minimum power
1. Open CO2 setting .
2. Set "Output" field to low output ("Low").
3. On models with two burners, select the "Cooking zone 1" field for
burner 1.
Service instructions
Gas technology
b Adjusting screw for maximum
power (4 mm Allen key or 1.2 x
6.5 mm screwdriver)
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents