Service menu - appliance test
No.
Basic setting
25
External core temperature
offset, sensor 1
26
External core temperature
offset, sensor 2
27
External core temperature
offset, sensor 3
28
External core temperature
offset, sensor 4
45
Generator mode
48
Steam elimination mode
49
Controls the cooking chamber
lamp when opening the
cooking chamber door
50
Controls the cooking chamber
lamp when closing the
cooking chamber door
602
Maximum power outage
duration for a warm start
607
Ready to Cook active
609
Interval for saving the
temperatures in the HACCP
log
618
Ready to Cook – Finished
message interval
624
SES status
625
Minimum duration of cooking
program for SES
655
Limitations for Arabic
662
Lock screen active
674
Auto-start
678
Scanner button available
695
PIN for operation lock
52
Standard
Range of
value
adjustment
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
0
0 = Off
1 = On
1
0 = Low
1 = Normal
2 = High
0
0-60 seconds
1
0-60 seconds
100 s
90 – 600
seconds
1
0 = Off
1 = On
120 s
1 – 180
seconds
60 s
0 – 300
seconds
1
0 = Off
1 = On
6 min.
4-6 minutes
0
0 = Off
1 = On
0
0 = Off
1 = On
0
0 = No auto-
start
1= Direct
favorites
2=Always
1
0 = Hidden
1= Visible
369
0 – 99999
Service instructions
Explanation
Ability to retrieve the saved temperature offset
values. The can also be changed and saved.
The calibration function in the Service menu is
used for calibration!
Only when using generators on ships.
"Low" setting: Minimum water consumption,
but higher condensate temperature and
greater steam volume. "High" setting:
Maximum water consumption, but lower
condensate temperature and smaller steam
volume.
Time within which the cooking program will
continue after interruption of the power supply.
When the value is "0", Ready2Cook is
permanently deactivated.
Reminder interval after the Ready2Cook
temperature is reached
When the value is "0", the SES function is
permanently deactivated.
If the overall duration of a cooking program is
less than this value, the SES does not run.
When the value is "1", no cooking programs
for pork are displayed
Display of Lock Screen menu item
Automatic start of a cooking program after
selection from AutoChef / Favorite
Display of scanner function in the title bar.