Gas technology
74
4. Press the "Start" button.
The burner status "Gas request" appears in green.
The burner status "Flame detected" appears in green.
The unit operates under partial load.
5. Measure the exhaust gas values with an approved exhaust gas
measuring device once the operating temperature is reached.
To regulate the cooking chamber temperature, open the
cooking chamber door slightly.
6. Check whether the measured CO
range.
7. Using the adjusting screw for minimum output, adjust the CO
content to the specified range for low output (setting is very
sensitive).
Turning counterclockwise: CO
Turning clockwise: CO
If necessary, repeat the adjustment procedure for maximum
power until the CO
minimum capacity is within the specified range.
8. On models with two burners: Repeat the procedure for the second
burner.
9. Check the exhaust gas values.
10.Press the "Stop" button.
The flame extinguishes.
The burner is off.
11.Press the Back button twice.
The main menu appears.
12.Switch off the unit.
Manually adjusting the rated heat input for maximum power
1. Set the unit to high output.
The unit operates at maximum power.
2. Measure the exhaust gas values with an approved exhaust gas
measuring device once the operating temperature is reached.
To regulate the cooking chamber temperature, open the
cooking chamber door slightly.
3. Check whether the measured CO
range.
4. Using the adjusting screw for maximum power, adjust the CO
content to the specified range for high output.
Turning counterclockwise: CO
Turning clockwise: CO
If necessary, repeat the adjustment procedure for minimum
power until the CO
minimum capacity is within the specified range.
5. On models with two burners: Repeat the procedure for the second
burner.
Service instructions
content is within the specified
2
content is decreased.
2
content is increased.
2
value at maximum capacity and at
2
content is within the specified
2
content is increased.
2
content is decreased.
2
value at maximum capacity and at
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents