INFORMATION
Prerequisite Gas connection line connected
Prerequisite Unit is in CO
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Setting with gas orifice (standard)
The offset pressure can be measured as an adjustment aid at minimum capac-
ity. This is not a substitute for making the basic gas setting.
Checked for leaktightness outside the unit
Connection pressure checked
Checked for leaktightness inside the unit
Basic gas setting checked
Left side wall removed
If the rated heat input is checked and not OK: adjust the rated
heat input.
a
Image: Setting the rated heat input
a Adjusting screw for minimum
capacity / low output (TX40)
settings.
2
1. Set "Output" field to low output ("Low").
2. On models with two burners, select the "Cooking zone 1" field for
burner 1.
3. Press the "Start" button.
The burner status "Gas request" appears in green.
The burner status "Flame detected" appears in green.
The unit operates under partial load.
The current cooking chamber temperature is displayed.
The burner's gas blower speed is displayed.
Service instructions
Gas technology
71