Connector X13 (potential-
free) optional
Connector X14 (potential-
Connector X15 / X16 Not in use
Connector X17 (208V AC)
Connector X19 / X20 Not in use
Connector X21 Reed contact switch for cooking chamber door B15
Connector X22 / X23 Not in use
Connector X24 B1 core temperature sensor 1
Connector X25 B2 cooking chamber sensor 1 (for 2xx upper chamber)
Connector X26 B3 cooking chamber sensor 2 (for 2xx lower chamber)
Connector X27 B4 Vapor sensor
Connector X28 B5 moisture sensor
Connector X29 (optional) B6 Sous Vide sensor, B7 core temperature sensor 2
Connector X31 (24V DC)
Connector X32 (24V DC)
Connector X35 Not in use
Button The buttons have no function and are intended for internal use.
Control for condensation hood via K10
No.
free)
1
Input K11, cooling fan G7 (208V AC)
2
Output K11, cooling fan G7 (208V AC)
No.
1
Output K8, solenoid M8
2
N for solenoid M8
No.
1
Output +, steaming unit valve 1
2
Output -, steaming unit valve 1
3
Output +, steaming unit valve 2
4
Output -, steaming unit valve 2
5
Output +, pressure switch B14
6
Input +, from pressure switch B14
7
0 V
No.
1/2
Output SSR 1
3/4
Output SSR 2
Service instructions