Henny Penny FlexFusion FPE-615 Service Instructions Manual page 50

Electric & gas platinum combi
Hide thumbs Also See for FlexFusion FPE-615:
Table of Contents

Advertisement

Service menu - appliance test
Relay
Connect
or
K1
X10
K1
X11
K2
X11
K4
X12
K5
X12
K6
X12
K8
X17
K17
X12
Dismantling and re-
programming
50
No.
Description
2
Main contactor Q1
1
POS A
2
POS B
3
Solenoid valve for vapor
quenching K12
4
Siphon pump G24
5
Backup relay K6
1
Lift magnet fresh air M8
1
Circulating pump G16
After changing the control board the original state is restored. Thus,
the backup relay is not used unnecessarily.
Establish the original condition of the wiring (from X12. 5 to Xx).
Calling up the "Backup relay" in the Service menu.
Select "OFF" using the roller.
The backup relay is deactivated.
Touch the "OK" field.
Changes saved.
Service instructions
Instruction
Re-connect the line from X10. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X11.1 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X11. 2 to X12. 5 and to
assign a reserve relay to it.
Re-connect the line from X12.3 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.4 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.5 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X17.1 to X12.5 and to
assign a reserve relay to it.
Re-connect the line from X12.1 to X12.5 and to
assign a reserve relay to it.