Gas technology
72
4. Measure the exhaust gas values with an approved exhaust gas
measuring device once the operating temperature is reached.
To regulate the cooking chamber temperature, open the
cooking chamber door slightly.
5. Check whether the measured CO
range.
6. Using the adjusting screw for minimum output, adjust the CO
content to the specified range for low output (setting is very
sensitive).
Turning counterclockwise: CO
Turning clockwise: CO
7. Set "Output" field to high output ("High").
The unit operates at maximum power.
8. Check whether the measured CO
range.
If necessary, repeat the adjustment procedure until the CO
value at high and at low output is within the specified range.
If the CO
level at high output is still outside the specified
2
range, the rated heat input must be set manually.
9. On models with two burners: Repeat the procedure for the second
burner.
10.Check the exhaust gas values.
11.Press the "Stop" button.
The flame extinguishes.
The burner is off.
12.Press the Back button twice.
The main menu appears.
13.Switch off the unit.
Service instructions
content is within the specified
2
content is decreased.
2
content is increased.
2
content is within the specified
2
2
2