Description of operation
INFORMATION
WaveClean termination
INFORMATION
12
6. A new water exchange of siphon content by means of the siphon
pump G24 and solenoid valve K12.
7. Start of rinsing.
Identical to step 5 (cleaning).
Differences: Heating of the cooking chamber to 92°C. The
second layer of wax melts in the WaveClean cartridge. The
rinse agent drops into the cooking chamber and mixes with
water.
Final rinse to bring the pH value to the normal level.
8. In the programs "normal" and "extra" additional drying of the
interior occurs by means of hot air.
9. Finally, an indicator for withdrawing the WaveClean cartridge
appears, and has to be confirmed.
Despite different cleaning durations, all cleaning steps require the same
amount of water.
During the cleaning process about 3 liters of water are provided by the steam-
ing unit into the oven.
WaveClean forced rinsing
The WaveClean forced rinse is automatically started by the operator in case of
failure or premature termination. The duration is 12 minutes. An entry is made
into the HACCP and in the diagnostic memory.