Memory Preset - Data Save/Load
The Save Data and Load Data programs make it easy to store and load charge and
discharge profiles for up to 10 batteries per channel. Data can be saved for each
battery type and each charge mode available with the X4 AC Pro. This allows you to
recall data for each battery when charging or discharging without having to set up
the program over again. You can also edit settings for each saved battery.
Save Data:
BATT/PROGRAM
BATT MEMORY
[ BATT MEMORY
ENTER SET ->
BATT TYPE
LiPo
Now you will set up the battery parameters. Use the INC or DEC buttons to
change the parameters then press ENTER/START to confirm your selection. Press the
INC button to move to the next parameter,
MAKE SURE TO FOLLOW YOUR BATTERY MANUFACTURERS
RECOMMENDATIONS REGARDING CHARGING AND DISCHARGING.
FAILURE TO DO SO MAY DESTROY THE BATTERY AND HAVE HAZARDOUS
Caution
RESULTS
BATT VOLTS
CHARGE CURRENT
32
From the BATT/PROGRAM menu use the INC or DEC
buttons to scroll to the BATT MEMORY program and
press the ENTER/START button to enter the battery
memory program.
In the corner of the screen you will see the number
1
]
1 flashing, use the INC or DEC buttons to select a
memory to program. Press the ENTER/START button
again to enter the memory setup menu.
Press the ENTER/START button again and the
battery type will begin to flash. Use the INC or DEC
buttons to select the battery type (LiPo, LiFe, LiIon,
LiHV, NiMH, NiCd or Pb, then press the ENTER/START
button to confirm your selection.
Voltage and Number of Cells: Enter the number of
7.4V (2S)
cells in the pack.
Charge Current: Enter the desired charge current.