HITEC X4 AC Pro Instruction Manual page 36

Ac/dc high output four port charging system
Hide thumbs Also See for X4 AC Pro:
Table of Contents

Advertisement

Warnings and Error Messages
In the event of an error or fault, the screen will display a message and emit an
audible sound.
REVERSE POLARITY
CONNECTION BREAK
CONNECT ERROR
CHECK MAIN PORT
BALANCE CONNECT
ERROR
DC IN TOO LOW
DC IN TOO HIGH
CELL ERROR
LOW VOLTAGE
CELL ERROR
HIGH VOLTAGE
CELL ERROR
VOLTAGE - INVALID
CELL NUMBER
INCORRECT
INT.TEMP.TOO HI
EXT.TEMP.TOO HI
OVER CHARGE
CAPACITY LIMIT
OVER TIME LIMIT
BATTERY WAS FULL
36
Incorrect polarity detected.
The connection to the battery has been broken.
The main battery connection is incorrect.
The Balance Cable on a Lithium Battery is not con-
nected.
The DC input voltage is less than the value set in
system settings.
The DC input voltage is higher than 18V.
Voltage in one of the cells in battery is too low.
Voltage in one of the cells in battery is too high.
Voltage in one of the cells in battery is invalid.
The number of cells is incorrect.
The internal temperature of the charger is too high.
The temperature of the battery is exceeding cut-off
limit set in sytem settings.
The battery capacity has exceeded the capacity cut-
off limit set in sytem settings.
The charging time has exceeded the safety timer
limit set in sytem settings.
The battery voltage is higher than the maximum volt-
age that has been set for balance charge mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents