Operation

Warming

Warming can be used to increase the print quality and enhance the restart printing.
It is important to ensure that the warming is not turned on accidentally, as this can
cause damage to the cartridge or a defective printed image.
The Warming can be activated by the iDESIGN software. The adjustment is in the
iDesign software under button „System settings"  tab „Advanced settings"  sub
menu „Warming"  menu „Warming".
If the warming is activated, the cartridges must be calibrated. The calibration of the
cartridge (temperature sensor in the cartridge) is necessary because the sensors in the
cartridge have large tolerances. The calibration is only necessary when the cartridges
are changed.
The calibration of the warming is only necessary when HP print heads are used.
When the warming function for LX- print heads is switched on, the correction is
made automatically. The Warming menu serves only to display the temperature.
The calibration is performed by Markoprint X4JET in the Service menu.
Display
In the line head temperature (Hd. Temp) the current temperature in the cartridge is
displayed.
If a value over 100 (149 or similar) is displayed there is no cartridge or a defective
cartridge is inserted.
After the calibration, the head temperature (Hd. Temp) shows the same value as the
ambient temperature (Ab. Temp) which reference sensor is located on the HP board in
the print head module. The temperature of the HP board is about 5 ° C higher than the
actual ambient temperature because the board warms up in the print head housing.
While the Warming menu is open, the warming is turned off. When the menu is left, the
warming will be reactivated.
Only calibrate cartridges with ambient temperature. Very cold or warm cartridges
falsify the result. It is the best to observe the temperature for a while (about a
minute) if the temperature is stable.
By every cartridge replacement (using a new cartridge), you have to reset the ink
level, so that the ink calculation / ink warning is working properly and calibration
must be performed.
To calibrate the head temperature, proceed as follows:
1.
Touch the iLOGIK once in one of the status menus.
 The Label submenu is displayed.
2.
Call the Service submenu by rotating the iLOGIK and select by pressing.
 The Reset Ink Cnt. submenu is displayed.
3.
Call the Head Temp. submenu by rotating the iLOGIK and select by pressing.
 The Head Temp. submenu is displayed.
Description
Ambient temperature – Temperature of the HP-Board in the head housing.
Head temperature – Temperature of the nozzle plate.
Head-ID – Identification number is used for service.
Seite 99 von 177
72800115 Markoprint X4JET