Operation
System setting:
The system must set up to the NSP function. That can be done by the iDesign software
below Settings
The function can set up for channel 1 (NSP Single head at head 1+2) or channel 2 (NSP
Single head at head 3+4) or channel 1+2 (NSP Single head at head 1+2 and NSP Single
head at head 3+4 or NSP Twin head at head 1-4).
If the function isn't need, the seeting must be set to „Off".
A Single head (12,5mm) can connect at channel 1, a second at channel 2.
Or a Twin head (25mm) can connect at channel 1+2.
A shaft encoder is recommended for a correct synchronisation.
Setup:
Example: A Single head at channel 1
Please set first the encoder resolution or speed exactly.
The test print image „Speedtest" can be used as an assistance.
For testing switch NSP off and set the system to 2x Single.
Assign both heads the same print image.
Both cartridges might be print on the same position.
For a fine-tuning adjust shaft encoder resolution or speed.
Then switch on the NSP and assign one of the cartridges the print image.
Start and assign print image:
To assign a print image one of the both cartridges must select firstly.
Move in the print image selection with the function key „F3".
Select the desired print image and start printing with „F1" (START) . Don't press „OK",
otherwise return again with 2x „F5".
System
NonStopPrinting.