Installation and initial operation
Installation must be performed by specialised staff:
1.
Set up the controller on an even and adequately load-bearing surface, mount on a tripod
or install it on a production line/wall with the optional available mounting brackets.
To mount the controller on a tripod on a production line or wall, 4 threaded inserts
are provided on the underside of the fork mount.
2.
Compare
the
 Chapter 0, Page 19 Connect only when the data corresponds!
1
3.
Connect the mains cable to the mains socket (Fig. 23/1) of the controller.
4.
Insert the mains plug into an earthed wall socket.
5.
If a rotary Encoder is installed, connect the rotary Encoder cable to the ENCODER socket
(Fig. 23/2) and tighten.
6.
Connect the light barrier cable to the SENSOR socket (Fig. 23/3) and tighten.
7.
Connect the print head cable of the first head (upper head) to the HEAD 1 socket (Fig.
23/4) and tighten.
8.
Connect the print head cable of the second head to the HEAD 2 socket (Fig. 23/5) and
tighten. Further print heads can be connect accordingly.
If only one print head is used, the other connection is not used.
9.
If a traffic light (accessory) is installed, connect the traffic light cable to the Alarm socket
(Fig. 23/6) and tighten.
10. If external inputs are installed, connect the input cable to the Extern socket (Fig. 23/7)
tighten.
mains
data
with
7
Seite 56 von 177
the
technical
data
6
3
2
4
72800115 Markoprint X4JET
of
the
controller.
1
3
6
5
Fig. 23: Controller, connection