6.5 Horn Replacement / Adjustment

Classification: Avery Dennison - Public
To remove the horn for replacement or adjustment:
1. Remove the sonic knife cover.
2. Remove the knife guard and the exit conveyor.
3. Remove the horn mount screws and horn clamp screws as shown in
Figure 19.
4. Remove the horn mount and horn clamp.
5. The horn will slide out from its mount.
To replace the horn:
1. When replacing the horn, before tightening the horn clamp screws, make
sure the horn is parallel with the knife blade.
2. Replace and tighten the horn mount screws.
3. Replace and tighten the horn clamp screws
4. Follow the procedure for leveling the knife blade.