Avery Dennison SONIC Knife Operator's And Service Manual page 26

1000w with telsonics
Table of Contents

Advertisement

26
   
Classification: Avery Dennison - Public
Leveling pin
When the horn face and knife blade are in brief contact, the ultrasonic
vibration over time will cause abrasion and eventually the knife blade
to wear. Therefore, the knife blade will need to be replaced
periodically.
1. Remove the knife blade guard.
2. The knife is attached to a self-leveling mount with a leveling
pin.
3. Loosen and remove the two knife screws.
4. Remove the blade from the leveling pin.
5. Replace the new knife blade.
6. Thread the two knife screws into the knife mount but do not
tighten.
7. Follow the knife blade leveling procedure each time the knife
blade is replaced.
NOTE: When removing the knife blade, the blade may seem tightly mounted
to the knife mount pin. Pull blade off of mount (leveling) pin by pulling from
the top of the blade.
User's Manual—Sonic Knife
Knife guard cover removed
Knife
screw
FIGURE 9