Alert Transfer Setting - Furuno FMD-3200-BB Instruction Manual

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

1. INITIAL SETTING AND ADJUSTMENT
1.7.3

Alert transfer setting

1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Alert Transfer Setting]  [IAS Setting] on the menu bar.
You can create the alert group and transfer the alert to the navigational equip-
ment. A maximum of ten alert groups ([Group001] to [Group010]) can be created,
and a maximum of 99 alerts can be registered to one alert group.
3. Select the appropriate alert group number ([Group001] to [Group010]) to transfer,
then set the following items.
Item
[Event Transmission] Select the alert to be transferred.
[Fixed Transmission]
[Periodic Interval (1 -
60 sec)]
[Sentence]
[Output 01(02)]
1-56
Alert registration field
• [Change Status Alert]: Transfer the alert whose status is
changed. For example, when alert problem is rectified and
alert status is changed from unrectified to rectified, alert is
transferred.
• [all target Alerts]: All alerts in the group are transferred.
Select the alert to be transferred periodically.
• [all target Alerts]: All alerts in the group are transferred period-
ically.
• [send "all occurred Alerts" or "ALR <null>, V,V"]: Transfer only
active alert periodically.
Set the interval to transfer the alert data.
Select the data type of alert notification, ALR or ALF.
Select Equipment ID of the destination equipment to transfer the
alert data. A maximum of two equipments can be assigned to the
destination.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents