5. RAYTHEON ANSCHUTZ AUTOPILOT NP-5400
5.1.2
NP-5400 alert and backup navigator setting
Use "Other Sensor" for the connection between the NP-5400 and the AMS. For exam-
ple, use [Other Sensor 1] for "Alert" as follows.
On the [Other Sensor - OTR001] setting screen, set [Alert Information Source] to [Alert
Sentence], and set [Sensor Name] to [Autopilot] or [NP-5400].
5.1.3
BNWAS setting
The BNWAS sub menu provides the necessary settings when both an AMS and a BN-
WAS are installed. Check [WAS001], then confirm settings.