Network Transmission Setting Between Ecdis And Radar - Furuno FMD-3200-BB Instruction Manual

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

1. INITIAL SETTING AND ADJUSTMENT
[Source]: Select the data source of [Heading] or [Other].
[Source (sub)]: Set the other data source in the same range as the data of [Head-
ing]. The [Source (sub)] appears only when the source of [Other] is not entered.
[Unit]: Set the unit in the [Heading] and [Other].
[Scale │ Range]: Set the display range of the X-coordinate. [Heading] is for the
range of the upper of the graph, [Other] is for the range of the lower of the graph.
[Time Span]: Set the display range of the Y-coordinate.
[Sample Interval]: Set the interval of the graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Change button]: Check the checkbox to show the [Change] button. Click the
[Change] button to show the [Vertical Heading Graph] hidden behind. Check the
checkbox of [Show] in [Change Button] of the component hidden behind.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the X-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
1.15
Network Transmission Setting Between
ECDIS and Radar
Connect the ECDIS and Radar (FAR-27/FAR-28/FCR-29/FAR-30 series)
with the LAN cable to show the radar echo and TT symbols on the ECDIS chart dis-
play, and show the ECDIS route and user chart symbol on the radar display.
For non-Furuno radar, the ECDIS chart display can not show the radar echo. The TT
symbol can be shown on the ECDIS chart display by connecting the ECDIS and radar
by serial interface.
Note: Confirm that the SPU board program version of the FAR-27/FCR-29 series
is version "03.50" or after.
For FAR-27, FCR-29 series
1. Turn on the DIP SW (S4) on the SPU board of FAR-27 and FCR-29 series.
The IP address of the radar processor unit is changed to "192.168.031.101".
2. To connect two antenna units, change the antenna number of second antenna
unit to "2" and set the IP address and subnet mask as shown below.
IP address: 192.168.031.102
Subnet mask: 255.255.255.0
3. Do one of the two procedures below according to the radar connected.
For FAR-27 series
1) Press the MENU key to open the main menu.
2) Press and hold the 1 HL OFF key, then press the MENU key five times to open
the [INITIALIZE] menu.
3) Open [8. OTHERS]  [5. INS], then select [LAN].
4) Go back to the [INITIALIZE] menu and open [6. TT PRESET]  [2. TT DATA
OUTPUT], then select [TTM], [TRUE] and [4800].
1-98

Hide quick links:

Advertisement

Table of Contents
loading