1.3 Distress Alert/Received Call Unit IC-305/
Alarm Unit IC-306
Mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the bottom chassis to the mounting location with four tapping screws (supplied).
3. Cable can be entered from bottom or rear panel. Select suitable entrance. For rear
panel entrance, change the clamp orientation as follows.
a) Unfasten two screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten two screws removed at step a) to fix the clamp.
Unfasten these screws.
4. Run the interconnection cable thru a cable entrance and connect it to terminal board.
Rotate.
Cable clamp, rotating
9
1. MOUNTING THE UNIT
Refasten screws.