Multiple Ecdis And Autopilot Control - Furuno FMD-3200-BB Instruction Manual

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

1. INITIAL SETTING AND ADJUSTMENT
1.6.4

Multiple ECDIS and autopilot control

The ECDIS is connected to the autopilot via a hardware switch to permit manual
switching of the ECDIS units.
For example, ECD002 is the primary ECDIS and ECD003 is secondary ECDIS. Then,
to set the primary and secondary ECDIS units, do as follows.
1. See section 1.6.3 to set the HCS for ECD002 and ECD003.
2. Click [TCS] on the tab bar, and then set [Primary] and [Secondary] as shown be-
low.
Setting Option
ECDIS
Autopilot
3. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
After rebooting the system, the [TCS] button appears on the InstantAccess bar
of ECD002 and ECD003. The [TCS] button on the ECDIS not selected as primary
ECDIS becomes inoperative (grayed out).
4. To switch the primary and secondary, switch from ECD002 to ECD003 with the
hardware switch and then click the radio button on the [TCS] menu of the ECDIS
menu.
The ECDIS checked at the TCS menu can engage the TCS.
Note: DO NOT switch ECDIS units while the TCS is engaged. Stop the TCS, then
switch the unit.
1-50
HUB-3000
EC-3000
HUB-100
(ECDIS)
Autopilot
Primary
ECD002
Secondary
ECD003
Manufacturer
Enter the manufacturer of the autopilot.
Model
Enter the type of the connected autopilot.
EC-3000
(ECDIS)
Hardware switch
Remarks
Off Course Limit
       Start:
      15.0
       Alert Threshold:
      30.0
MIN Maneuvering Speed:
4.0 kn