Ams] Menu; Ams Mode Operation - Furuno FMD-3200-BB Instruction Manual

Setting and adjustments
Hide thumbs Also See for FMD-3200-BB:
Table of Contents

Advertisement

1. INITIAL SETTING AND ADJUSTMENT
Menu item
[Output Route File
Format]
[Source SFID]
1.7

[AMS] Menu

The AMS menu sets up the interface between the AMS (Alert Management System)
and the processor unit, including the AMS operating mode.
Note 1: For Chart Radars, only the settings on the [Operation Mode Setting] window
are required (see section 1.7.1).
Note 2: For how to set the alert definition of AMS, see the FURUNO information.
1.7.1

AMS mode operation

1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Operation Mode Setting] on the menu bar.
item
[Alert Monitoring In-
terval]
[Disable Alert Time-
out Clear] (01 to 05)
[Output Data Type
For INS]
[Enable Category A
Buzzer]
[Buzzer Pattern]
1-54
Select whether the channel limit is symmetrical or asymmetrical.
This setting is available when [Output Route Data Setting] is set to
[File and RMB].
• [Symmetrical]: The channel limit is symmetrical.
• [Asymmetrical]: The channel limit is asymmetrical.
Select the additional SFID when CCRS outputs the sentence from
the TCS ([ECDIS SFID] or [TCS SFID]).
Set the time to wait before clearing the corresponding alert when
communication with a sensor is interrupted.
Select the units where the alert is not to be cleared.
Select the data type of alert notification, ALR or ALF.
Select if the alert buzzer sounds when the alert of Category A oc-
curs.
Sets the buzzer sound pattern to output when an alert occurs.
[INS]:
• Alert priority = "Alarm": Three short beeps, four seconds mute,
then repeat.
• Alert priority = "Warning": Two short beeps, four seconds
mute, then repeat.
[Legacy]:
• Alert priority = "Alarm" or "Warning": Alarm sounds continuous-
ly.
Description
Remarks

Hide quick links:

Advertisement

Table of Contents
loading