05- 00
Preset Speed Control mode Selection
【0】:Common Accel / Decel.
Range
【1】: Individual Accel/Decel for each preset speed 0-7.
05- 01
Preset Speed 0
05- 02
Preset Speed 1
05- 03
Preset Speed 2
05- 04
Preset Speed 3
05- 05
Preset Speed 4
05- 06
Preset Speed 5
05- 07
Preset Speed 6
05- 08
Preset Speed 7
【0.00 ~ 599.00】 Hz
Range
05-17
Preset Speed 0 Acceleration time
05-18
Preset Speed 0 Deceleration time
05-19
Preset Speed 1 Acceleration time
05- 20
Preset Speed 1 Deceleration time
05- 21
Preset Speed 2 Acceleration time
05- 22
Preset Speed 2 Deceleration time
05- 23
Preset Speed 3 Acceleration time
05- 24
Preset Speed 3 Deceleration time
05- 25
Preset Speed 4 Acceleration time
05- 26
Preset Speed 4 Deceleration time
05- 27
Preset Speed 5 Acceleration time
05- 28
Preset Speed 5 Deceleration time
05- 29
Preset Speed 6 Acceleration time
05- 30
Preset Speed 6 Deceleration time
05- 31
Preset Speed 7 Acceleration time
05- 32
Preset Speed 7 Deceleration time
【0.1 ~ 3600.0】s
Range
When 05- 00 =【0】Accel /Decl 1 or 2 set by parameters 00-14/00-15 or 00-16/00-17 apply to
all speeds.
When 05- 00 =【1】Individual Accel/Decel apply to each preset speed 0-7. Parameters 05-17
to 05-32.
Formula for calculating acceleration and deceleration time:
V/F mode:
Actual Acc time =
Actual Dec time =
SLV mode:
Actual Acc time =
05- Preset Frequency Selections
(Keypad Freq)
Time of Accel 1 or 2 x Preset Frequency
V/F Max Frequency
Time of Decel 1 or 2 x Preset Frequency
V/F Max Frequency
Time of Accel 1 or 2 x Preset Frequency
Motor rated output frequency