Download Print this page

gefran BDI50 Series User Manual page 97

Compact v/f & sensorless inverter

Advertisement

04-11
Analog Output (AO) function selection.
Range
【0】:Output frequency
【1】:Frequency Setting
【2】:Output voltage
【3】:DC Bus Voltage
【4】:Output current
Example: Set 04-11 required according to the following table.
10V
A
5 V
Xmax / 2
0
Xmax( 04-11)
04-12
AO Gain
【0 ~ 1000】%
Range
04-13
AO Bias
【0 ~ 100】%
Range
04-14
AO Bias Selection
【0】: Positive
Range
04-15
AO Slope
【0】: Positive
Range
 Select the Analog output type for the multifunction analog output on terminal (TM2)
as required by parameter 04-11. Output format is 0-10V dc.
The output voltage level can be scaled and modified by parameters 04-12 to 04-15 If
necessary.
 The modification format will be same as the examples shown previously for Analog Voltage
Input (AVI) parameters 4-02 to 4-05.
Note: the max output voltage is 10V due to the hardware of the circuit.
Use external devices that require a maximum of 10V dc signal.
04-16
Potentiometer / frequency curve gain setting
【0 ~ 1000】%
Range
04-17
Potentiometer / frequency curve bias (offset) setting
【0 ~ 100】%
Range
04-18
Potentiometer / frequency curve bias (offset) signe selection
【0】: Positive
Range
04-19
Potentiometer / frequency slope of the curve selection
【0】: Positive
Range
 Setting of frequency (main / alternative) by potentiometer on integrated keypad.
04-11
【0】
【1】
【2】
【3】
Xmax
【4】
【1】: Negative
【1】: Negative
【1】: Negative
【1】: Negative
4-50
A
Output frequency
Frequency Setting
Output voltage
DC Bus Voltage
Output current
Xmax
upper frequency limit
upper frequency limit
Motor Rated Voltage
220V:0~400V
380V:0~800V
2 times rated current
of inverter

Hide quick links:

Advertisement

loading