Download Print this page

gefran BDI50 Series User Manual page 59

Compact v/f & sensorless inverter

Advertisement

No.
Description
Low Frequency Torque
02-15
Gain
SLV Without Load Slip
02-16
Compensation Gain
SLV With Load Slip
02-17
Compensation Gain
SLV With Load Torque
02-18
Compensation Gain
SLV Slip
02-19
Compensation Select
No.
Description
03-00
Multifunction Input Term. S1
03-01
Multifunction Input Term. S2
03-02
Multifunction Input Term. S3
03-03
Multifunction Input Term. S4
03-04
Multifunction Input Term. S5
03-05
Up/Down frequency band
03-06
03-07
Up/Down Frequency modes
03-08
S1~S5 scan confirmation
03-09
S1~ S5 switch type select
Group 02- Motor parameters
0~100
0~200
0~200
0~200
0: Slip Compensation 1
2: Slip Compensation 2
Group 03- Multi function Digital Inputs/Outputs
0:Forward/Stop Command or Run
/Stop
1:Reverse/Stop Command Or
REV/FWD
2:Preset Speed 1 (5-02)
3:Preset Speed 2 (5-03)
4:Preset Speed 4 (5-05)
6:Jog Forward Command
7:Jog Reverse Command
8:Up Command
9:Down Command
10:Acc/Dec 2
11:Acc/Dec Disabled
12:Main/Alternative Run Command
select
13:Main/Alternative Frequency
Command select
14:Rapid Stop ( Decel to stop)
15:Base Block
16:Disable PID Function
17:Reset
18:Auto Run Mode enable
0.00~5.00
0:Preset frequency is held as the
inverter stops, and the UP/Down
function is disabled.
1:Preset frequency is reset to 0 Hz
as the inverter stops.
2:Preset frequency is held as the
inverter stops, and the UP/Down is
available.
1~200. Number of Scan cycles
xxxx0:S1 NO xxxx1:S1 NC
xxx0x:S2 NO xxx1x:S2 NC
xx0xx:S3 NO xx1xx:S3 NC
x0xxx:S4 NO x1xxx:S4 NC
Range
Range
Reserved
4-12
Factory
Unit
Setting
50
%
by series
%
150
%
100
%
0
Factory
Unit
Setting
0
-
1
-
2
-
3
-
17
-
0.00
Hz
0
-
10
ms
00000
-
Note
Note

Hide quick links:

Advertisement

loading