Download Print this page

gefran BDI50 Series User Manual page 135

Compact v/f & sensorless inverter

Advertisement

Display
Err2
Parameter setting
error
Err5
Modification of
parameter is not
available in
communication
Err6
Communication
failed
Err7
Parameter conflict
5.1.3 Special conditions
Display
StP0
Zero speed at stop
StP1
Fail to start directly
On power up.
StP2
Keypad Stop
content
1. 00-13 is within the range
of (11-08 ±11-11)
OR (11-09 ±11-11)
OR (11-10 ±11-11)
2. 00-12≦00-13
3. 00-05/00-06 or 00-00 /
10-01 set the same value
4. Modifying parameters
01-01~01-09 when
01-00≠ 7.
5. a.If this parameter is
parameterized for both
functions (AVI/PTC) at
the same time.
b.PTC function is
enabled by setting
08-10≠0.
6. Parameter password
function (13-07) set
incorrect.
1.Control command sent
during communication.
2.Attempt to modify the
function 09-02~ 09-05
during communication
1.Wiring error
2.Communication
Parameter setting error.
3.Incorrect communication
protocol
1.Attempt to modify the
function 13-00/13-08.
2. Voltage and current
detection circuit is
abnormal.
Fault
STP0 is a message displayed on keypad (and on
communication) to signal to the user that the motor doesn't
move because the preset frequency is very low.
In V/f mode, STP0 comes out at less than 1.3Hz (50Hz set)
and at less than 1.5Hz (60Hz set)
In SLV mode, STP0 comes out at less than 1Hz.
1. If the inverter is set for external terminal control mode
2. The inverter cannot be started and will flash STP1.
3. The run input is active at power-up, refer to descriptions
1. If the Stop key is pressed while the inverter is set to
Cause
(00-02/00-03=1) and direct start is disabled (07-04=1)
of (07-04).
5-4
Corrective action
1. modify11-08~11-10 or 11-11
2. 00-12>00-13
3.set 00-05 / 00-06 or 10-00 /
10-01 to be different value
4.set 01-00=7
5.PTC function source can not
be the same as frequency
source or PID command via
AVI.
6. Please set correct password
1.Issue enable command
before communication
2.Set parameters 09-02~
09-05 function before
communication
1. Check hardware and wiring
2.Check Functions(09-00~
09- 05).
If reset is not possible, please
consult with the supplier.
Description

Hide quick links:

Advertisement

loading