3.6.2 Description of control circuit terminal
Size 1 & Size 2
Terminal symbols
RA
RB
COM
24V
S1~S5
10V
AVI
ACI
AO
AGND
NPN:
RA RB COM S1
PNP:
RA RB +24V S1
TM2 Function Description
Relay output terminal
S1~S5 (COMMON) 【NPN】
S1~S5 (COMMON) 【PNP】
Multi-function input terminals
(refer to group 3)
Built in Power for an external speed
potentiometer
Analog voltage input
Specification : 0 / 2~10 VDC
(choose by parameter 04-00)
Analog current input
Specification : 0 / 4~20mA
(choose by parameter 04-00)
Multi function analog output terminal.
Maximum output 10VDC/1mA
Analog ground terminal
S2
S3
S2
S3
250VAC/1A (30VDC/1A)
±15%,Max output current 30mA
24 VDC, 4.5 mA, Optical coupling
isolation (Max,voltage 30 Vdc,
Input impedance 6kΩ)
10V (Max current:20mA)
0~10V (Input impedance 200kΩ)
0~20mA (Input impedance 499Ω)
0~10V (Max current 2mA)
S4
S5
10V AVI ACI
S4
S5
10V AVI ACI
3-30
Signal Level
AO AGND
AO AGND