3.4 Specifications
3.4.1 Product Specifications
230V Class : Single phase.
Sizes BDI50
Rated Output Capacity
Rated Output Current
Maximum Applicable Motor
Output Voltage
Output Frequency
Rated Voltage, Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
(1)
Input current
Allovable momentary
power loss time
Enclosure
230V Class : Three phase
Sizes BDI50
Rated Output Capacity
Rated Output Current
Maximum Applicable Motor
Output Voltage
Output Frequency
Rated Voltage, Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
(1)
Input current
Allovable momentary
power loss time
Enclosure
(1) The input current is calculated value at full rated output current.
F : Standards for built-in filter
1004
kVA
1.0
A
2.6
HP
0.5
kW
0.4
V
Hz
Based on parameter setting 0.01~599
Single-Phase, 200V to 240V, 50/60Hz
A
7.2
s
1.0
1007
2015
kVA
1.65
A
4.3
HP
1
kW
0.75
V
Hz
Based on parameter setting 0.01~599
Three-Phase, 200V to 240V, 50/60Hz
A
6.4
s
1.0
3-19
1007
2015
1.65
4.3
1
0.75
Three-Phase, 0 to 240V
+10% ~ -15%
±5%
11
15.5
1.0
IP20
2022
3037
2.90
4.00
6.67
7.5
10.5
17.5
2
3
5
1.5
2.2
3.7
Three-Phase, 0 to 240V
+10% ~ -15%
±5%
9.4
12.2
19.3
2.0
2.0
2.0
IP20
2022
2.9
4.0
7.5
10.5
2
3
1.5
2.2
21
2.0
2.0
4055
4075
9.91
13.34
26
35
7.5
10
5.5
7.5
28.6
38.5
2.0
2.0

Hide quick links: