00- 05
Main Frequency Command Source Selection
00- 06
Alternative Frequency Command Source Selection
【0】: UP/DOWN of Keypad
【1】: Potentiometer on Keypad
【2】: External AVI Analog Signal Input
【3】: External ACI Analog Signal Input
Range
【4】: External Up/Down Frequency Control
【5】: Communication setting Frequency
【6】: PID Output frequency
When 00-06 =[6], frequency command source is output of the PID.
00- 07
Main and Alternative Frequency Command Modes
【0】: Main Or Alternative Frequency.
Range
【1】: Main frequency + Alternative Frequency
When 00-07=【0】, the frequency source is set by the Main frequency parameter 00-05 (Default)
or by the Alternative frequency parameter 00-06.
Use any of the external terminals S1 to S5 and set the relevant parameter 03-00 to 03-04 =【13】to
switch from main to Alternative source.
When 00 - 07 =【1】The Frequency command will be the SUM of Main & alternative frequencies.
I.e:
Main frequency setting=10Hz
Alternative frequency setting= 5Hz
If 00-07=0, frequency setting will be 10Hz OR 5 Hz
If 00-07=1, frequency setting will be 10Hz + 5 Hz = 15Hz
00- 08
Communication Frequency Command
【0.00~599.00】Hz
Range
This parameter can be used to read the set frequency in communication mode
This parameter is only effective in the communication mode.
00- 09
Frequency Command save on power down (Communication mode)
【0】: disable
Range
【1】: enable
00-09=【0】 Keypad frequency is saved.
00-09=【1】 Frequency set by communication is saved.
00-10
Initial Frequency Selection
【0】: By Current Freq Command
【1】: By Zero Freq Command
Range
【2】: By 00-11
00-11
Initial Frequency Setpoint
【0.00~599.00】Hz
Range
This parameter is only effective in keypad mode..