Installation and Connection
4.6

Operator

As an accessory to the local or external (option: cable 00.F5.0C0-1xxx) operation of the COMBIVERT R6-S, an
operator is necessary. To prevent malfunctions, the COMBIVERT must be brought into nOP status before con-
necting/ disconnecting the operator (open control release). When starting the COMBIVERT, it is started with the
last stored values or factory setting.
X6C
5 4 3 2 1
5
4
3
2
1
9
8
7
6
9 8 7 6
RS 232 cable
Part number
00.58.025-001D
Length 3 m
Digital operator (part number 00.F5.060-1000)
Interface operator (part number 00.F5.060-2000)
x x 5-digit LED Display
x x Operating-/Error display
Normal "LED on"
Error "LED blinks"
-
x Interface control
Transmit "LED on"
x x Double function keyboard
-
x X6B HSP5 programming and diagnostic inter-
face
-
x X6C RS232/RS485
Only use the operator interface for the serial data transfer to RS232/485. The direct
connection, PC to the COMBIVERT is only valid with a special cable (part number
00.F5.0C0-0001) otherwise it would lead to the destruction of the PC-interface !
PIN RS485
Signal
1
-
-
2
-
TxD
3
-
RxD
4
A'
RxD-A
5
B'
RxD-B
6
-
VP
7
C/C'
DGND
8
A
TxD-A
9
B
TxD-B
9-pole Sub-D socket
to the PC
Meaning
reserved
Transmission signal RS232
Receive signal RS232
Receive signal A RS485
Receive signal B RS485
Voltage supply +5 V (Imax=50 mA)
Data reference potential
Transmission signal A RS485
Transmission signal B RS485
3
2
5
Housing (PE)
START
ENTER
FUNC.
F/R
SPEED
STOP
X6B
C O M B I V E R T
X6C
X6D
9-pole SUB-D connector
2
3
to the operator
7
GB - 33