Technical Data - KEB Combivert R6 Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for Combivert R6:
Table of Contents

Advertisement

Technical Data

3.
Technical Data
Unit size
Housing size
Phases
Rated voltage
Mains voltage range
Mains frequency
DC voltage range
Regenerative operation
Output rated power
Rated active power
Max. power output
Max. active power
Regenerative rated current
Regenerative DC current
Over load current (E.OL) 60 s
Max. regenerative DC current 60 s
Power supply operation
Input rated power
Rated active power
Max. input power
Max. active power
Rated supply current
DC supply current
Overload current (E.OL) 60s
Max. DC supply current 60s
Overload disconnection (E.OL)
Overvoltage switch-off (E.OP)
Max. permissible DC link capacity
Max. permissible total circuit component current
(I
)
nOP
Max. permissible mains fuse type gR
I
t Integral of the limiting load of the semicon-
2
ductor
Perm. gR fuse Siemens Sitor (no delta power system)
Max. permissible DC fuse Siemens Sitor type aR
Short-circuit factor at the connection point (S
Power loss at nominal operating
Max. heat sink temperature
1) Lay two connection cables parallel at a regenerative current > 230 A DC .
2) The overcurrent is specified for 1 minute. The overload cycle is 300 seconds. This corresponds to duty class 2 EN 2‑60146‑01.
3) The current data are based on a fundamental frequency component of g=0,95. The fundamental frequency component or the effective value of
the input current is dependent on load and line supply conditions. At uncontrolled B6 converters the phase angle cosφ1 can be set to one, so the
value of the fundamental frequency components is equal to the value of the power factor.
4) Please contact KEB for higher values.
Voltage stabilization must be activated at the inverter if a harmonic filter is used.
The units are not short circuit proof without corresponding dimensioned fuses
Exceeding of the max. rechargeable DC link capacity can lead to a defect.
A load removal in the DC link circle may be done only after the message „ready".
GB - 12
[V]
[V]
[Hz]
[V
]
DC
[kVA]
[kW]
[kVA]
[kW]
[A]
1)
[A
]
DC
2)
[A]
[A
]
DC
[kVA]
[kW]
[kVA]
[kW]
3)
[A]
1)
[A
]
DC
[A]
[A
]
DC
[%]
[V
]
DC
4)
[µF]
[A
]
AC
[A]
[A
s]
2
/S
)
mains
N
[W]
[°C]
25
R
3
400
305...528 ±0 %
50 / 60 ±2
420...747 ±0 %
153
140
230
210
221
270
331
405
153
135
230
202
221
270
331
405
160
800
50000 (400 V class) 35000 (480 V class)
≤6
315
39000
3NE1230-0
see options
<350
1300
88