Resetting Or Re-Establishing The Parameters; Resetting After Replacing The Pcb; Auto-Detecting Options And Accessories; Reverting To The Commissioning Settings - REMEHA GAS 120 ACE Series User Manual

Mid control box equipped with a hmi t-control
Hide thumbs Also See for GAS 120 ACE Series:
Table of Contents

Advertisement

9.7

Resetting or re-establishing the parameters.

9.8

Accessing information on the hardware and software versions

Component
Appliance Info
CU-GH-08
HMI T-control
MK3 -
7717201 - v03 - 25062019
On
On
On
On
On
Description
Information about the boiler
Information about the boiler central unit PCB
Information about the control panel
When you have saved the commissioning settings, the option Revert
commissioning settings is available in the Advanced Service Menu.
9.7.1

Resetting after replacing the PCB

Configuration numbers must be reset if the boiler or burner safety unit
PCB is replaced.
The configuration numbers can be found on the data plate of the boiler.
To reset the configuration numbers:
1. Press the
key.
2. Select Advanced Service Menu > Set Configuration Numbers.
3. Select CU-GH-08.
4. Select and change the CN1 setting.
5. Select and change the CN2 setting.
6. Select Confirm to confirm the modifications.
9.7.2

Auto-detecting options and accessories

Use this function after replacing a boiler PCB in order to detect all the
devices connected to the CAN bus.
To detect devices connected to the CAN bus:
1. Press the
key.
2. Select Advanced Service Menu > Auto Detect.
3. Select Confirm to carry out the auto-detect.
9.7.3

Reverting to the commissioning settings

If the commissioning settings were saved, you can revert to the values
specific to your installation.
To revert to the commissioning settings
1. Press the
key.
2. Select Advanced Service Menu > Revert commissioning settings.
3. Select Confirm to revert to the commissioning settings.
9.7.4

Reverting to the factory settings

To revert to the factory settings for the boiler:
1. Press the
key.
2. Select Advanced Service Menu > Reset to Factory Settings.
3. Select Confirm to revert to the factory settings.
Information on the hardware and software versions for the appliance's
various components is stored in the control panel.
To access:
1. Press the
key.
2. Select Version Information.
3. Select the component for which you would like to see the version
information.
MID _HMI T-control - Gas 120 ACE