8 Operation
Menu
ComfortZoneDHWtemp
Zone configuration > Domestic Hot Water Setpoints
Fig.55
14 : 23
Zo...
Zone setup...
DHW1: DHW Schedule
Sunday
6:00
Comfort
55.0°C
Edit schedule entry
6:00
Comfort
55.0°C
Add time and Activity
Copy to other day
Set activity temperatures
44
MID _HMI T-control - Gas 120 ACE
8.8.3
You can modify the "Comfort domestic hot water" and "Reduced domestic
hot water" set point temperatures.
1. Select the
Off
2. Select one of the following menus:
8.8.4
Activating timer programming mode
In order to use the timer programme, the timer programming (Scheduling)
mode must be activated. This is activated for each zone individually.
1. Select the icon for the DHW
Off
2. Select Zone configuration > OperatingZoneMode > Scheduling.
Creating a timer programme for domestic hot water
A timer programme can be used to vary the domestic hot water
temperature depending on activities during the day. This can be
programmed for each day of the week.
1. Select the
Off
2. Select Zone configuration > DHW Schedule.
3. Select the programme to be modified.
4. Select the day to be modified.
5. Carry out the following actions according to your needs:
MW-2000750-2
Selecting a timer programme
In the Timer programming operating mode, three programs are available.
To select a timer programme:
1. Select the
Off
2. Select Scheduling.
3. Select the desired timer programme.

Modifying the domestic hot water set point temperatures

icon for the DHW zone.
Description
Only modify the "Comfort domestic hot water" set point tem­
perature
Modify the "Comfort domestic hot water" and "Reduced do­
mestic hot water" set point temperatures.

Timer programming for domestic hot water

icon for the DHW zone.
The programmed activities for Sunday are displayed.
The last activity of the day remains active until the first activity of the
following day.
Modify the timings for programmed activities.
Add a new activity.
Delete a programmed activity (choose the activity "Delete").
Copy programmed daily activities to other days.
Modify temperatures linked to an activity.
icon for the DHW zone.
zone.
7717201 - v03 - 25062019