Release Input; Connecting External Sensors; Connecting A Tank Sensor Or Thermostat - REMEHA GAS 120 ACE Series User Manual

Mid control box equipped with a hmi t-control
Hide thumbs Also See for GAS 120 ACE Series:
Table of Contents

Advertisement

Fig.30
to CB-09
BL
RL
Fig.31
Tdhw Tflow
Tout
Fig.32
to SCB-02
Tdhw Tflow
Tout
7717201 - v03 - 25062019
PWM
Tout
-
+
MW-2000874-01
0-10
0-10
R-Bus
-
+
MW-2000932-01
0-10
0-10
R-Bus
-
+
MW-2000923-01
5.3.11

Release input

The boiler has a release input (normally open contact). This input relates
to the RL terminals of the connection terminal block.
If this contact is closed when there is a heat demand, the boiler will be
blocked after a waiting time.
Change the waiting time of the input by configuring the AP008 parameter.
Important
Only suitable for potential-free contacts.
5.3.12

Connecting external sensors

Tdhw Tank sensor (NTC 10 k Ohm)
Tflow Boiler flow temperature sensor (NTC 10 k Ohm)
Tout Outdoor temperature sensor (NTC 10 k Ohm)
The sensor connection contacts are dry contacts.
5.3.13

Connecting a tank sensor or thermostat

A sensor or thermostat can be connected to the Tdhw terminals of the
connector.
1. Connect the domestic hot water sensor or the tank thermostat to the
Tdhw connector.
MID _HMI T-control - Gas 120 ACE
5 Installation
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gas 120 ace - 65Gas 120 ace - 90Gas 120 ace - 115

Table of Contents