Increasing The Domestic Hot Water Temperature Temporarily; Maintaining The Installation; Viewing The Service Notification; Reading Out Measured Values - REMEHA Gas 210 Ace 80 Service Manual

High-efficiency standing gas boiler
Hide thumbs Also See for Gas 210 Ace 80:
Table of Contents

Advertisement

4 Installer instructions
Fig.18
The heating curve
11:20
...
.....
.... ......
.... ...... ....
A
...... ...
B
... ....
... ...
C
.... ...
....
.....
........ ...................
4.5.5

Increasing the domestic hot water temperature temporarily

4.6

Maintaining the installation

4.6.1

Viewing the service notification

4.6.2

Reading out measured values

16
D
AD-3001402-01
5. Adjust the following parameters:
Tab.14
Settings
A
Slope:
Slope of the heating curve:
B
Max:
Maximum temperature of the heating circuit
C
Base:
Ambient temperature setpoint
D
xx°C ; xx
Relationship between the heating circuit flow
°C
temperature and the outdoor temperature. This
information is visible throughout the slope.
You can temporary increase the hot water temperature when the time
program is active with the reduced temperature setpoint. Use this to
deviate from the time program or testing of the hot water production.
> Installation Setup > Internal DHW > Hot water boost >
Duration of temporary overwrite
Use the rotary knob to navigate.
Use the
button to confirm your selection.
1. Press the
button.
2. Select Installation Setup.
3. Select Internal DHW.
4. Select Hot water boost.
5. Select Duration of temporary overwrite.
6. Set the duration in hours and minutes.
The hot water temperature is increased to the DHW comfort
setpoint.
You can abort the temporary increase by selecting Reset.
When a service notification appears on the display, you can view the
details of the notification.
Use the rotary knob to navigate.
Use the
button to confirm your selection.
1. Select the tile [
].
The View Service Notification menu opens.
2. Select the parameter or value you want to view.
The appliance continually registers various measured values from the
system. You can read these values on the control panel.
> Installation Setup > select zone or device > Parameters,
counters, signals > Counters or Signals
Use the rotary knob to navigate.
Use the
button to confirm your selection.
1. Press the
button.
Underfloor heating circuit: slope between 0.4
and 0.7
Radiator circuit: slope at approximately 1.5
7837115 - v.01 - 10012023

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gas 210 ace 120Gas 210 ace 160Gas 210 ace 200