OBID i-scan
8.4. Fujitsu ISO15693 MB89R118 Custom Commands
8.4.1. [0xA0] EAS Command
On EAS command reception, the transponder returns the response code repeated six times after the
specified flag (0x00) if the EAS bit is 1. If the EAS bit is 0 the transponder returns no response. The
EAS command can be executed only when the transponder is in the ready or selected state. The re-
sponse code value is 0x5A
REQUEST-DATA
5
0xA0
MODE
RESPONSE-DATA (STATUS = {0x95})
(5-10)
Response
Code(6 times)
MODE:
Bit:
Function
ADR:
Response-Code value:
This byte is only available if EAS bit is set. Value = {0x5A} 6 times sent,
else there is no response from tag.
8.4.2. [0xA1] Write EAS
This command writes the EAS bit.
REQUEST-DATA
5
0xA2
MODE
RESPONSE-DATA (STATUS = {0x95})
5
ISO-ERROR
MODE:
Bit:
Function
FEIG ELECTRONIC GmbH
System-Manual
6
7
6
-
-
ADR
b000
non-addressed
b001
addressed
b010
selected
6
(7-14)
UID
7
6
-
-
5
4
-
-
7/15
DATA
5
4
-
-
Page 93 of 131
ID ISC.MR/PR/PRH101
3
2
1
-
ADR
3
2
1
-
ADR
H60301-3e-ID-B.doc
0