Feig Electronic OBID i-scan ID ISC.PRH102-B Installation Manual
Feig Electronic OBID i-scan ID ISC.PRH102-B Installation Manual

Feig Electronic OBID i-scan ID ISC.PRH102-B Installation Manual

Hide thumbs Also See for OBID i-scan ID ISC.PRH102-B:

Advertisement

®
INSTALLATION
OBID i-scan
ID ISC.PRH102-B
final
public (B)
2010-06-29
M91101-0e-ID-B.doc

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic OBID i-scan ID ISC.PRH102-B

  • Page 1 ® INSTALLATION OBID i-scan ID ISC.PRH102-B final public (B) 2010-06-29 M91101-0e-ID-B.doc...
  • Page 2 FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
  • Page 3: Table Of Contents

    4.1.4. Reset - button ID ISC.PRH102-B ................11 5. Technical Data 6. Approvals 6.1. Europe (CE)........................15 6.2. Declaration of Conformity ....................16 6.3. USA and Canada (FCC and IC)..................17 7. Appendix 7.1. Accessories ........................18 7.2. Scope of delivery.......................18 FEIG ELECTRONIC GmbH Page 3 of 18 M91101-0e-ID-B.doc...
  • Page 4: Safety Instructions / Warning - Read Before Start-Up

    Special advice for carriers of cardiac pacemakers: Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pacemaker. FEIG ELECTRONIC GmbH Page 4 of 18 M91101-0e-ID-B.doc...
  • Page 5: Performance Features Of The Id Isc.prh102

    2.2. Available Reader-Types Following Reader-Types are available at present: Reader-Types Description ID ISC.PRH102-B Bluetooth interface with internal antenna and voltage supply by means of 4 rechargeable Mignon AA batteries Table 1: Reader-Types FEIG ELECTRONIC GmbH Page 5 of 18 M91101-0e-ID-B.doc...
  • Page 6: Control And Display Elements

    The switch of the reader can be configured by the software. In the standard configuration the serial number of the Transponder is read and is sent to the host after pressing the scan - button. FEIG ELECTRONIC GmbH Page 6 of 18 M91101-0e-ID-B.doc...
  • Page 7: Led

    LED violet „INITIALIZING internal Bluetooth interface“ (red & blue) - Turns on during writing bluetooth parameters in internal bluetooth interface. Table 2: Standard configuration of the LEDs FEIG ELECTRONIC GmbH Page 7 of 18 M91101-0e-ID-B.doc...
  • Page 8: Assembly And Wiring

    Table 3: Standard configuration of the Bluetooth Interface Note: Until FECOM.DLL version 2.8.8 the COM-Port setting “Char Timeout Multiplier” from PC or Notebook should be increased to 9-10 if a Bluetooth reader is used. FEIG ELECTRONIC GmbH Page 8 of 18 M91101-0e-ID-B.doc...
  • Page 9: Supply Voltage

    • Reversed polarity may destroy the device. • Rechargeable batteries should never be discarded with normal trash; please return them to a proper collection location ! Fig. 2: Inserting the rechargeable batteries FEIG ELECTRONIC GmbH Page 9 of 18 M91101-0e-ID-B.doc...
  • Page 10: Charging The Batteries

    Outside Minus – charge voltage Table 5: Charger connection Note: • Reversing the polarity of the charger can destroy the batteries. • The Reader is not functional while the batteries are charging. FEIG ELECTRONIC GmbH Page 10 of 18 M91101-0e-ID-B.doc...
  • Page 11: Reset - Button Id Isc.prh102-B

    After activating the Reader with the Scan button the “paired connection” entry in Bluetooth interface is cleared by holding the Reset button down for longer than 4 seconds until the violet LED light up. FEIG ELECTRONIC GmbH Page 11 of 18 M91101-0e-ID-B.doc...
  • Page 12 Reader activation Reset Scan Longer than 4 sec “Bluetooth parameters” Button Reset Button Longer than 4 sec Status Reader Reader activation Clear Scan “paired connection” Button Reset Button Longer than 4 sec FEIG ELECTRONIC GmbH Page 12 of 18 M91101-0e-ID-B.doc...
  • Page 13: Technical Data

    Current Draw max. 0,5 A • max. 2,5 VA Power Consumption • Operating Frequency 13,56 MHz • Transmitting Power 200mW ± 1dB • internal antenna Antenna • Bluetooth (Serial port profile) Interface FEIG ELECTRONIC GmbH Page 13 of 18 M91101-0e-ID-B.doc...
  • Page 14 FCC 47 CFR Part 15 – Canada IC RSS-GEN, RSS-210 • ETSI EN 301 489 • Safety - low voltage EN 60950 - Human Exposure EN 50364 • Fall Withstands multiple 5´/1,5 m drops to concrete FEIG ELECTRONIC GmbH Page 14 of 18 M91101-0e-ID-B.doc...
  • Page 15: Approvals

    When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/5/EC dated March 99. Equipment Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 15 of 18 M91101-0e-ID-B.doc...
  • Page 16: Declaration Of Conformity

    ® OBID i-scan Installation ID ISC.PRH102 6.2. Declaration of Conformity FEIG ELECTRONIC GmbH Page 16 of 18 M91101-0e-ID-B.doc...
  • Page 17: Usa And Canada (Fcc And Ic)

    Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 18: Appendix

    7.2. Scope of delivery Reader Scope of delivery - Reader ID ISC.PRH102-B ID ISC.PRH102-B - Quick user guide Table 8: Scope of delivery Note: Rechargeable batteries and battery charger are not included in delivery FEIG ELECTRONIC GmbH Page 18 of 18 M91101-0e-ID-B.doc...