OBID i-scan
8.2.3. [0xA2] Get Log Status
This command reads the status flags for the logging of the measurement values.
REQUEST-DATA
5
0xA2
MODE
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
RESPONSE-DATA
5
Logflags
Logpointer
MODE:
Bit:
Function
ADR:
UID:
Read-only serial no. of the transponder. The UID is required only in the addressed mode.
ISO-ERROR:
ISO error code of transponder response. This byte is only available if STATUS = 0x95.
Logflags: The type of measurement.
Logpointer: Pointer of the next measurement value
LogLimitLo: Lower limit for measurement value
LogLimitHi: Higher limit for measurement value
Logperiode: Range of the measure.
Timerticks: Defines how many times the measurement interval runs off.
FEIG ELECTRONIC GmbH
System-Manual
6
(7-14)
UID
6
7-8
LogLimitLo
7
6
-
-
ADR
b000
non-addressed
b001
addressed
b010
selected
9-10
11-12
LogLimitHi
Logperiode
5
4
-
-
Page 86 of 131
ID ISC.MR/PR/PRH101
13-14
Timerticks
3
2
1
-
ADR
H60301-3e-ID-B.doc
0