• Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at any
time. It answers then with the configured address.
• Not available by the USB-Reader
1
BAUD
:
By means of this byte the baud rate of the asynchronous interface can be defined.
5:
4800 baud
6:
9600 baud
7:
19200 baud
8:
38400 baud
Note:
Changing of BAUD only becomes effective after writing / saving configuration block
CFG1 to EEPROM and a reset of the Reader.
• The Reader set the baud rate to 38400 baud, if the user set an invalid baudrate.
• Not available by the USB-Reader
2
TRANS-FORM
:
By means of this byte, several parameters for the data transmission format of the asynchro-
nous interface can be defined.
Bit:
Function:
P:
Kind of Parity
b00:
b01:
b10:
b11:
D:
Number of Data Bits
b0:
b1:
S:
Number of Stop Bits
b0:
b1:
1
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.
2
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.
FEIG ELECTRONIC GmbH
System-Manual
7
6
5
0
0
0
no Parity
even Parity
odd Parity
- do not use -
8 Data Bits
- do not use -
1 Stop Bit
- do not use -
Page 22 of 131
4
3
2
0
S
D
ID ISC.MR/PR/PRH101
1
0
P
H60301-3e-ID-B.doc